Controller Settings:
1. Set the DMX value of Channel 1 to a value of 7.
2. Set the DMX value of Channel 2 to a value of 7 or 8. When Channel 2 is
set to "7" you can adjust the starting address between 1 and 255. When
set to "8" you can adjust the starting address between 256 and 511.
3. Use Channel 3 to set your desired DMX starting address.
4. Wait for approximately 20 seconds for the unit to complete the address
reset function.
Example 1:
If you want to set the starting address to 57, set Channel 1 to a value of “7”,
set Channel 2 to a value of “7” and use Channel 3 to set your address to 57
by selecting a channel value of 57.
Example 2:
If you want to set the starting address to 420, set Channel 1 to a value of “7”,
Channel 2 to "8" and Channel 3 to "164" (256+164=420).